Brand Name : MeCan
Model Number : MCA-301
Certification : ISO
Place of Origin : Guangzhou
MOQ : 1 set
Price : Inquiry
Payment Terms : L/C, T/T, Western Union,Paypal,Cash
Supply Ability : 5000 sets per month
Delivery Time : 3-15 working days
Packaging Details : standard packing
Product : Anesthesia device
Type : Electronically controlled, Pneumatic driven
Patient spectrum : Pediatric to bariatric
Mode of ventilation : VCN, SIGH, SIMV, Stand-by, Manual, PEEP(Optional)
Hypoxic guard system : N2O cut-off valve, O2 concentration no less than 25%
Safety valve : <12.5kpa
Monitoring : VT, MV, BPM, Paw, FiO2, Lung compliance
Waveform : Pressure-time, flow-time, pressure-volume loop, volume-time (Optional), flow-volume loop (Optional)
Power : AC 220V±10%, 50Hz±2%, built-in battery support
Gas : O2, N2O, air (Optional)
Specification Of Surgical Anesthesia:
1. Anesthesia Machine
2. VT MV BPM Paw FiO2 Lung compliance Morniting
3. 8.4 Inch LCD display
4. VCN SIGH SIMV Stand-by Manua
Main Feature
1. Applied for closed, semi-closed, semi-open inhalation anesthesia, controlled or assisted ventilation, monitoring and
display patients’ ventilation parameters
2. Applied for adult and pediatric
3. Integrated anesthetic ventilation system, APL security air relief valve is available
4. Vaporizers: 2.
Advanced temperature, flow and pressure compensation technology, Isofurane, Enfurance, Halothane and Sevoflurance as per option.
5. 8.4” TFT-LCD display screen
Main Specification:
Type: Electronically controlled, Pneumatic driven
Patient spectrum: Pediatric to bariatric
Mode of ventilation: VCN, SIGH, SIMV, Stand-by, Manual, PEEP(Optional)
Hypoxic guard system: N2O cut-off valve, O2 concentration no less than 25%
Safety valve: <12.5kpa
Monitoring: VT, MV, BPM, Paw, FiO2, Lung compliance
Waveform: Pressure-time, flow-time, pressure-volume loop, volume-time (Optional), flow-volume loop (Optional)
Power: AC 220V±10%, 50Hz±2%, built-in battery support
Gas: O2, N2O, air (Optional)
Alarm: Optimal multi-class alarm unit, VT beyond limitation, upper and lower limitation of ventilation, upper and lower limitation of ventilation, upper and lower limitation of airway pressure, asphyxiation, current failure, gas source hypotonic, gas circuit abnormity, upper and lower limitation of CO2 concentration (Optional)
Prompt and protection: Prompt for parameter limitations, protection for unreasonable parameter setting.
![]() |